Thermostatic Cartridge for Victoria Plumb Concealed and Exposed Shower Valves
| Cartridge Total Length | 119.2mm (i.e. 11.92cm). This could be measures as 120mm or 12cm if not using callipers. |
|---|---|
| Diameter At Widest Metal Point | 47.6mm |
| Number of O Rings | 4 |
| Material | Brass |
| Type | Screw in (screws into the shower valve and has a thread on top of the cartridge which allows a fixing nut or plate to connect onto). |
| Gauze Filters | 2 |
| Number or Teeth | 24 |
Please contact us if you have any questions regarding the Victoria Plumb thermostatic cartridge or need assistance in matching shower or tap valve parts.
+ You can also reach us on WhatsApp (07754 173340).
We are here to help with your spares needs!
Question: My shower was fine up until a few days ago but now it only has one temperature: Scalding hot! What do you think the problem is?
Answer: The first thing you should do is check to see whether the shower valve is receiving a constant flow of hot and cold water. Usually, there isn't a problem with cold water flow unless there is something blocking the cold water pipe.
If cold water is reaching the shower and water temperature is still piping hot then the issue here will be the Victoria Plumb thermostatic cartridge. The thermostatic cartridge is the heart of the valve which mixes the hot and cold water together to output the desired temperature.
Your shower valve is only outputting piping hot water which means the cartridge isn't mixing the hot and the cold. The cartridge you have has now worn out and needs replacing. A new Victoria Plumb thermostatic cartridge should make your shower run like new and you shouldn't experience this problem anymore.
Question: There is water leaking out of the front of the Victoria Plumb thermo cartridge from where the handle connects onto the cartridge.
Answer: From your description it sounds like the water is leaking from the silver-coloured e-circlip. If this is the case then there are some seals within the heart of the cartridge which have failed. If these seals have failed, other parts of the cartridge will have worn and will need replacing so a new cartridge for Victoria Plumb is required.
Question: I'm only getting cold water coming out of the shower even though I know the shower is getting hot water.
Answer: The problem will be the thermostatic cartridge so you'll need to replace it. Hot and cold water is entering the valve and into the thermostatic cartridge but at this point, the cartridge isn't working so the water is outputting at the temperature at which the cartridge failed at.
Question: Can I return the thermostatic cartridge for Victoria Plumb showers if it the wrong size?
Answer: Yes, you can return any of our spares within 14 days as long as it is in a re-saleable condition.
Question: Is the cartridge actually in stock?
Answer: If the cartridge says it is in stock, we can assure you we have it in stock in our UK facilities.
Other Victoria Plumb shower parts compatible with this thermostatic cartridge:
We accept the following payment methods:
We use industry-standard payment systems to help keep your payment information secure. Our website and payment processes are regularly checked to maintain PCI security standards.