The 07025000-CS is a replacement on/off flow-control cartridge for the GROHE 07025000 valve used in selected shower mixers, bath/shower mixers and concealed valves. This listing is for replacement spare 07025000-CS, distinct from the separately listed original-reference part GR-07025000.
The cartridge controls the opening and closing of the water supply through the flow-control assembly. In thermostatic mixers, it performs a different function from the thermostatic cartridge that regulates water temperature. It is also separate from a bath-to-shower diverter, which selects the outlet.
| Part Number | 07025000-CS |
|---|---|
| Original valve reference | 07025000 |
| Part type | on/off flow-control cartridge |
| Nominal valve size | 3/4 inch |
| Application | replacement for the specified 07025000 screw-down flow-valve arrangement in shower mixers, bath/shower mixers and concealed valves |
Identify the original flow-valve reference and exact mixer model before ordering. Compare the existing cartridge's shape, threaded connection and handle engagement with the product photographs. The nominal 3/4-inch size alone does not establish fitment, and a shared Grohtherm or Automatic 2000 range name is not sufficient to identify the correct valve.
For 19657000 and 34963000 installations, check whether the existing flow valve is 07025000 or the separately specified ceramic valve 45885000. Do not assume that these different valve references are interchangeable.
The following applications use the original 07025000 flow valve. Select 07025000-CS only where that original valve reference and the installed arrangement have been identified.
Symptom: water continues dripping from the shower head or spout after the control is turned off. Likely cause: the flow valve is not sealing correctly; the condition of the valve seat should also be checked. Solution: identify the installed flow valve, inspect the sealing arrangement and replace the faulty component as appropriate. A new cartridge will not repair a damaged valve-body seat.
Isolate the water supply before removing the existing cartridge. Follow the servicing instructions for the exact mixer, check the seating and threads, and test for leaks and correct shut-off after reassembly. A temperature-control fault requires separate diagnosis rather than automatically replacing the on/off valve.
These are separate service parts for the specific mixer arrangements listed above, not a common service kit for every application. Select additional parts against the exact model and installed components. Sharing the 07025000 flow valve does not establish that two mixers use the same thermostatic cartridge, handles or non-return valves.
Unsure which flow cartridge is installed? Use the Di Vapor part-identification service and provide the mixer model, photographs of the controls and clear photographs of the removed cartridge, including its threaded section and spindle.
We accept the following payment methods:
We use industry-standard payment systems to help keep your payment information secure. Our website and payment processes are regularly checked to maintain PCI security standards.