Genuine Grohe 47450000 1/2" SDT Thermo Element thermostatic cartridge for Chiara, Clova, Ectos, Europlus, Grohtherm, Auto, Sentosa and Taron shower mixer valves.
Include:
Also known as:
The yellow plastic part in the photo is a protective cap covering the handle spline.
Measurements:
| Cartridge Length | 86.7mm |
|---|---|
| Diameter | 31.8mm |
| Number of O'Rings | 2 |
| Material | Brass |
| Installation Type | Screw-Fit |
| Gauze Filters | 0 |
Other information:
| Manufacturer | Grohe |
|---|---|
| Spare Part | Thermo-Element Cartridge 47450000 |
| Installation | Screw In |
| Material | Brass and Stainless Steel |
The Grohe 47450000 Cartridge is used in the following Grohe series:
This Grohe shower thermostatic cartridge spare can be dispatched on the same working day if purchased before 3:00 PM.
Di Vapor supplies a huge selection of Grohe spare parts.
Q: Is the 47405000 similar to the 47450000?
A: Both of the cartridges are identical except for the length of its stem. The 47405000 replacement part has a longer stem than the Grohe 47450000 Thermo Element thermostatic cartridge.
Q: Is this replacement part a genuine Grohe replacement part?
A: This is indeed a genuine Grohe spare part.
The instructions here are for the Grohe Automatic 2000 bath mixer.
1: Switch off hot and cold water supplies.
2: The right end side of the housing contains the thermostatic cartridge. Remove the cap to uncover the adjustment screw. Undo the screw to remove the cap.
3: Take off the gray shroud using a screwdriver.
4: With the shroud off, latch a 24mm spanner on the thermostat cartridge and turn it counterclockwise to loosen.
5: Use a cloth or a small brush to clean the valve housing.
6: Apply silicone grease on the o-rings of the new Grohe 47450000 cartridge. Fit the cartridge in the valve housing. Use a spanner and turn it clockwise to tighten.
7: Reposition the gray shroud and screw back the black fitting.
8: Put back the cap and washer then re-screw the adjustment screw.
9: Turn both hot and cold water supplies on and calibrate until the water temperature is an optimal 38℃ or 100.4℉.
To calibrate: Open the tap and use a digital thermometer to check if the water temperature is 38℃ (100.4℉). If the temperature is higher or lower a tepid 38℃, undo the adjustment screw and change the position on another spline. This involves repeated attempts until the preferred temperature is achieved.
10: Restore the cap.
We accept the following payment methods: