Big price drop for clearance.
S960025NU Ideal Standard / Trevi 1/2 Inch Ceramic Disc Flow Cartridge 1/4 turn (On/Off) Pack of 2
| Includes | 1 x Anti-Clockwise Close Catridge and 1 x Clockwise Close Cartridge |
|---|---|
| Manufacturer | Ideal Standard |
| Spare Part | Tap Flow Cartridge 1/2 Inch; Set of Two (S960025NU) |
| Installation | Screw In |
| Material | Brass |
| Total Length | 56.7mm |
| Number of Splines / Teeth | 18 |
| Length of top Spindle | 25.1mm |
| Width of Top Spindle | 7.7mm |
| Width at Widest Point | 23.8mm |
| Width at Thread (below o ring) | 20.8mm |
| Markings on some versions of the cartridge | PPO-GF-30 |
The Ideal Standard S960025NU pack of two flow cartridge is available for dispatch on the same day when ordered before 3:00 PM, from Monday to Friday. Each set pack has one piece counterclockwise close cartridge E960582NU and an E960583NU which closes clockwise.
This is a list of taps that use the Ideal Standard / Trevi spare part.
S960025NU Ideal Standard flow cartridge is also suitable for:
Cartridges, as does tap models, come in different shapes and sizes. Di Vapor provides a very wide range of Ideal Standard spare parts. Knowing the correct spare part that corresponds with the tap model is important.
If you do not know your tap’s particular model or part number of the cartridge needed, gather relevant information by measuring the cartridge diameter, length, stem, and count the number of splines. If measuring is not possible, photograph the cartridge and show it your spare part provider.
You can reach us through WhatsApp (07754 173340). Di Vapor has super friendly spares experts who are happy to serve your spares needs.
Q: I have a tap and the pressure has dropped on the cold water so was thinking the tap may have scaled up. Would I need a new tap or a replacement S960025NU Ideal Standard cartridge?
A: It's difficult to call it without seeing the tap, it could be the cartridge or a build-up of limescale.
Leaks or poor water flow are among the signs a tap flow cartridge requires a new replacement. Usually, a good quality cartridge can last for years. The main factor that shortens the lifespan of a cartridge is the level of water hardness. Over time, high levels of chalk and minerals can develop around and inside the cartridge. Accumulated debris will clog the cartridge and causing poor water flow.
Eventually, due to imminent wear-and-tear, cracks in the cartridge or O-rings will transpire and will result in a leaky tap.
These are the common steps for replacing an S960025NU tap cartridge:
1: Isolate cold and hot water supply lines. If isolation switches cannot be found, turn the main valve off. This can generally be found near the water meter. Once it is switched off, open the tap to see if the water supply is fully isolated.
2: If the handles are embellished with a cold and hot indicator, remove it by popping it out by hand or using a small blunt instrument to prevent scoring the handle’s finish.
3: With the indicator out, you can now access the small screw underneath the indicators. Use a screwdriver to undo the screws and remove the tap handle.
If there are no decorative indicators, the screw is often located at the back or below the handle.
4: There may or may not be a shroud covering the cartridge. If there is a shroud, it can be hand tight and can be taken off by turning it anticlockwise. If the shroud is locked in place with a screw, use a hex key to undo the grub screw. Remove the shroud.
5: Without the shroud, the top of the flow cartridge can be seen. Grip the cartridge with a spanner and rotate anticlockwise to dislodge it. A small amount of leftover water may seep out.
6: Clean the inside of the tap valve unit using a cloth or a brush.
7: Grease the new Ideal Standard / Trevi S960025NU cartridge with silicone grease and set the cartridge in the valve unit. Use a spanner to tighten.
8: Reinstall the shroud, tap handle, and the decorative cold and hot indicators.
9: Turn both water supply pipes on and test if the S960025NU installation is merrily completed.
Check the exact tap model and compare the cartridge code, spline arrangement and measurements with the part being removed. The clockwise-close and anti-clockwise-close cartridges should not be assigned universally to hot or cold, as their positions vary between tap assemblies.
Isolate the water supplies before removing the old cartridges. Clean the cartridge housing before installation and apply a suitable silicone grease to the O-ring and bottom seal where required.
Not sure which part you need? Use the Di Vapor part identification service.
We accept the following payment methods:
We use industry-standard payment systems to help keep your payment information secure. Our website and payment processes are regularly checked to maintain PCI security standards.