Triton 83310660 Compatible Thermostatic Cartridge for Leona and Fontana Shower Mixer Bars
| Manufacturer | Triton |
|---|---|
| Product | Thermostatic Cartridge Spare Part |
| Installation | Push-Fit with Grub Screw |
| Number of External O-Rings | 3 |
Cartridge Measurements:
| Total Length | 91.4mm (including wax thermostat at bottom) |
|---|---|
| Diameter at Widest Point | 33.8m |
| Top Spline Diameter | 9.6mm |
| Top Spline Teeth / Notches | 24 |
| Diameter at Top O'ring | 33.5mm |
| Diameter at Middle O'ring | 31.8mm |
| Diameter at Bottom O'ring | 30.1mm |
| Fitting Type | Push Fit with M5 (5.7mm) Grub Screw (Grub Screw Not Included) |
Triton spare part thermostatic cartridge 83310660 has been discontinued, but, it is available on Di Vapor. This cartridge is compatible with Triton exposed shower units:
If the spare part for the cartridge you are using is no longer available and you want it to be repaired or reconditioned, please message us with a clear photo of the cartridge. We will communicate with you to let you know if it can be serviced.
The three Triton showers, Mesca, Fontana, and Leona, are very similar to each other. The replacement procedure for the three is the same.
First, before proceeding to the replacement repair, turn off the shower’s cold and hot water supply lines. You may also plug your bath drain to keep the screws from tumbling in.
1. Remove the temperature knob assembly by unscrewing the centre screw.
2. Please note where the “stop” is located. Or take a snapshot of it for the reassembly process.
3. Undo the grub screw to release the cartridge.
4. As a layer of protection against abrasion, apply a thin coating of plumbing lubricant on the O-rings of the replacement Triton 83310660 thermostatic cartridge.
5. Fit the cartridge in the shower unit and secure the grub screw.
6. Switch on the cold and hot water supplies.
7. Set the temperature control knob on top of the splines.
8. Turn on the flow control to its maximum. With the water running, use a thermometer to check the temperature.
9. Rotate the spindle to the left to increase the temperature and to the right to decrease the temperature. Repeat this step until you achieve the temperature you prefer.
10. Return the stop ring in the same position as in step 2 – the stop must point at 12:00.
11. Refit the temperature knob and screw to secure.
The 83310660 Triton thermostatic cartridge can be shipped via next day delivery when you place an order earlier than 3 in the afternoon on a weekday.