Bristan SK1850-2 TS1850 Head Work.
| What | Shower outputs only one water temperature. |
|---|---|
| Why | Calcified sediments can be detrimental to the condition of the shower valve and its parts. The abrasiveness of the sediments may have damaged parts of the Bristan SK1850-2 and the thermostat is no longer working. |
| How | Replace the Bristan SK1850-2 TS1850 head work and SK1500-3 wax thermostat and piston. The complete cartridge assembly is also available. |
| What | Reduced water flow. |
| Why | There might be an airlock. A blockage in the shower valve, hose or shower head. A blocked SK1850-2 Bristan TS1850 head work. |
| How | Opening all showers and taps in a home can release the airlock. Check the shower valve, hose and shower head for any blockages. Replace the head work. |
| Why | Leaking from the handle. |
| Why | Worn-out Bristan SK1850-2 TS1850 cartridge seals. |
| How | Replace the seal kit (SK1850-1). |