Triton LP (Low Pressure) Thermostatic Shower Cartridge Replacement
| Diameter | 84mm |
|---|---|
| Total Heigth | 117mm |
When replacing this cartridge you may encounter difficulties so please note the following:
1. The new cartridge will come with locating pins which are designed to align the cartridge into the valve correctly. Older models of this valve do not have holes in the brass body for the locating pins (the newer versions do), therefore if you don't have holes for the locating pins, snap the plastic locating pins off the cartridge. This can be done with a pair of pliers.
2. If you find that you have installed the cartridge and water is leaking, it is because it hasn't sealed properly. This is a common occurrence when replacing this cartridge. To resolve this, simply take the cartridge out and refit it until the problem is solved.