This Inta NC25XXX thermostatic self closing cartridge is the replacement service part used in the NC250CP thermostatic non concussive basin mounted mixer tap with adjustable temperature control.
In the NC250CP assembly this cartridge manages the thermostatic mixing and timed self-closing operation, and the servicing instructions state that it should be removed and replaced as a complete self-contained unit.
| Part Number | NC25XXX |
|---|---|
| Part type | thermostatic non-concussive self closing cartridge |
| Application | Inta NC250CP timed flow thermostatic basin mixer tap |
| Timed flow in the NC250CP tap | 15 seconds +/- 5 seconds at 1 bar |
| Factory set outlet temperature for the NC250CP tap | 41C |
| Operating pressure for the NC250CP tap | 1.0 to 5.0 bar |
| Maximum inlet temperature for the NC250CP tap | 65C |