Vado FL-803-33/2X-CD is a 31mm diverter cartridge used in selected VADO bath shower mixer and diverter valve assemblies including OMI-133, OMI-135 and NOT-232 valves. This cartridge controls outlet selection and is used where the valve diverts water between bath and shower outlets.
A worn or damaged diverter cartridge can cause poor outlet selection, stiff operation or water passing to the wrong outlet. A common symptom of diverter cartridge failure is water dripping from the shower head or spout when the shower or tap is turned off or when the diverter should be isolating that outlet.
Technical Details
- - Part Number: FL-803-33/2X-CD
- - Cartridge type: Diverter cartridge
- - Total length: 53mm
- - Main diameter: 31mm
- - Diameter at widest point: 32.8mm
- - Splines: 20 with 18 visible
- - Spline diameter: 7.6mm
Confirmed Compatible Models
- - OMI-133
- - OMI-135
- - NOT-232
Before Order Checks
- - Match the code FL-803-33/2X-CD and compare the cartridge length, body diameter, spline count and spline diameter before ordering.
- - Check that the fault is with the diverter function rather than the main mixer cartridge, flow cartridges, handle assembly or seals.
- - Apply silicone grease suitable for cartridge o-rings and bottom seals during fitting.
Related Spares You May Need
- - TACSIL 3g Premium Cartridge Silicone Grease - WRAS Approved
Di Vapor accepts the following payments methods: