Roca A525012503 Thesis Diverter Cartridge for Bath Shower Mixers
The Roca A525012503 is a diverter cartridge used in selected Roca Thesis-T, Targa-T and T-5000 / Panama-T thermostatic bath/shower mixers, as well as the Evolution A2H0416000 hydromassage thermostatic column.
This cartridge operates the outlet-selection mechanism, directing water to the selected outlet. In the specified bath/shower mixers, it forms part of the diverter and flow-control arrangement. It is separate from the thermostatic cartridge that regulates the mixed water temperature.
Technical Details
- - Part number: A525012503
- - Component type: Diverter cartridge
- - Application: Outlet selection in the specified thermostatic bath/shower mixers and hydromassage column
Confirmed Models
- - Roca Thesis-T 5A1150C00 exposed thermostatic bath/shower mixer
- - Roca Thesis-T 5A2850C00 concealed thermostatic bath/shower mixer
- - Roca Targa-T 5A2860C00 concealed thermostatic bath/shower mixer
- - Roca T-5000 / Panama-T 5A1108C00 exposed thermostatic bath/shower mixer
- - Roca T-5000 / Panama-T 5A1108C02 exposed thermostatic bath/shower mixer
- - Roca T-5000 / Panama-T 5A2208C00 concealed thermostatic bath/shower mixer
- - Roca T-5000 / Panama-T 5A2808C00 concealed thermostatic bath/shower mixer
- - Roca Evolution A2H0416000 hydromassage thermostatic column
Before Ordering
Check the exact mixer or column reference and confirm that its parts diagram specifies A525012503. Compare the original cartridge's spindle, body and sealing arrangement with the product photographs. The range name or cartridge diameter alone is not sufficient to identify the correct part. Check whether your repair also requires a retaining nut or separate seals before ordering.
Fault Finding
Poor outlet switching, water passing to an unselected outlet or persistent dripping from the shower head or bath spout after the control is turned off are reasons to check the diverter and its seals. Confirm the source of the fault before changing the cartridge. This is not the thermostatic temperature-control cartridge.
Related Spares You May Need
- - Roca A525017303 Thermostatic Cartridge - Cartridge Only: Separate temperature-control cartridge used in the Thesis-T 5A2850C00 and Targa-T 5A2860C00 mixers
- - TACSIL 3g Premium Cartridge Silicone Grease - TAC86: For lubricating cartridge O-rings and seals during servicing
Installation Note
Isolate both water supplies before removing the old cartridge. Follow the instructions for the exact mixer or column, then check for leaks and correct outlet operation after fitting.
Use the Di Vapor part identification service for help finding the right part.