INTA NC300CP Pushtap Non-Concussive Self Timed Tap Cartridge with Gasket - 15 sec. @ 1 bar
The INTA NC300CP is a Pushtap non-concussive self timed tap cartridge supplied with gasket for selected Inta timed-flow basin and wall-mounted taps.
This cartridge controls the push-button timed flow and self-closing action of the tap. It is specified as 15 seconds at 1 bar, making it suitable for Inta Pushtap applications where controlled water run time is required.
Technical Details
- - Part code: NC300CP
- - Di Vapor Part Number: IN-NC300CP
- - Timed flow: 15 sec. @ 1 bar
- - Approximate overall length: 78mm
- - Approximate length of white plastic section: 19mm
- - Approximate widest point of white plastic section: 24mm
- - Approximate external thread diameter: 25.5mm
Used In
- - Inta NC180CP Basin Mounted Mixer Tap with Temperature Control Spare Parts
- - Inta NC160CP Non Concussive Basin Mounted Standard Tap (Pairs) Spare Parts
- - NC160CP(S) Basin Mounted Non-Concussive Taps
- - NC165CP 3 Second Basin Mounted Non-Concussive Taps
- - Inta NC165CP(S) Basin Mounted Non Concussive Tap 3 Sec (Single) Spare Parts
- - Inta NC170CP Non Concussive Wall Mounted Tap (Pairs) Spare Parts
- - Inta NC160CPS5 Non-Concussive Basin-Mounted Standard Tap (Single) 5 Litre Per Min Spare Parts
Before You Order Check
Check the existing tap model, cartridge code, timed-flow requirement and thread size before ordering. This cartridge is for the listed Inta non-concussive timed tap applications and should not be selected from measurements alone.
Common Fault Symptoms
- - Symptom: tap will not shut off correctly after being pressed. Likely Cause: worn or sticking timed cartridge. Solution: replace the NC300CP cartridge and gasket.
- - Symptom: water flow stops too quickly or runs for too long. Likely Cause: failed timed-flow cartridge or incorrect operating pressure. Solution: confirm system pressure and replace the cartridge if the tap assembly is correct.
- - Symptom: water leaks around the push tap cartridge area. Likely Cause: worn cartridge gasket or damaged seal area. Solution: inspect the seating area and replace the cartridge with its gasket where required.
Di Vapor accepts the following payments methods:
Di Vapor treats your privacy and security with the utmost importance. The payment systems used by Di Vapor are based on industry standards to ensure all payments are securely handled. In fact, we ensure the Di Vapor website is regularly checked to guarantee compliance to PCI security standards.